[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [PATCH for-4.15] x86/dmop: Properly fail for PV guests



Andrew Cooper writes ("[PATCH for-4.15] x86/dmop: Properly fail for PV guests"):
> The current code has an early exit for PV guests, but it returns 0 having done
> nothing.

Reviewed-by: Ian Jackson <iwj@xxxxxxxxxxxxxx>

> diff --git a/xen/arch/x86/hvm/dm.c b/xen/arch/x86/hvm/dm.c
> index 5bc172a5d4..612749442e 100644
> --- a/xen/arch/x86/hvm/dm.c
> +++ b/xen/arch/x86/hvm/dm.c
> @@ -365,6 +365,7 @@ int dm_op(const struct dmop_args *op_args)
>      if ( rc )
>          return rc;
>  
> +    rc = -EINVAL;
>      if ( !is_hvm_domain(d) )
>          goto out;

Is this style, of setting rc outside the if, the standard hypervisor
style ?

Ian.



 