[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [Xen-devel] PCI Device Subtree Change from Traditional to Upstream



On Wed, Jan 03, 2018 at 05:10:54PM -0600, Kevin Stange wrote:
> On 01/03/2018 11:57 AM, Anthony PERARD wrote:
> > On Wed, Dec 20, 2017 at 11:40:03AM -0600, Kevin Stange wrote:
> >> Hi,
> >>
> >> I've been working on transitioning a number of Windows guests under HVM
> >> from using QEMU traditional to QEMU upstream as is recommended in the
> >> documentation.  When I move these guests, the PCI subtree for Xen
> >> devices changes and Windows creates a totally new copy of each device.
> >> Windows tracks down the storage without issue, but it treats the new
> >> instance of the NIC driver as a new device and clears the network
> >> configuration even though the MAC address is unchanged.  Manually
> >> booting the guest back on the traditional device model reactivates the
> >> original PCI subtree and the old network configuration with it.
> >>
> >> The only thing that I have been able to find that's substantially
> >> different comparing the device trees is that the device instance ID
> >> values differ on the parent Xen PCI device:
> >>
> >> PCI\VEN_5853&DEV_0001&SUBSYS_00015853&REV_01\3&267A616A&3&18
> >>
> >> PCI\VEN_5853&DEV_0001&SUBSYS_00015853&REV_01\3&267A616A&3&10
> >>
> >> Besides actually setting the guest to boot using QEMU traditional, is
> >> there a way to convince Windows to treat these devices as the same?  A
> >> patch-based solution would be acceptable to me if there is one, but I
> >> don't understand the code well enough to create my own solution.
> > 
> > Hi Kevin,
> > 
> > I've got a patch to QEMU that seems to do the trick:
> > 
> > From: Anthony PERARD <anthony.perard@xxxxxxxxxx>
> > Subject: [PATCH] xen-platform: Hardcode PCI slot to 3
> > 
> > Signed-off-by: Anthony PERARD <anthony.perard@xxxxxxxxxx>
> > ---
> >  hw/i386/pc_piix.c | 2 +-
> >  1 file changed, 1 insertion(+), 1 deletion(-)
> > 
> > diff --git a/hw/i386/pc_piix.c b/hw/i386/pc_piix.c
> > index 5e47528993..93e3a9a916 100644
> > --- a/hw/i386/pc_piix.c
> > +++ b/hw/i386/pc_piix.c
> > @@ -405,7 +405,7 @@ static void pc_xen_hvm_init(MachineState *machine)
> >  
> >      bus = pci_find_primary_bus();
> >      if (bus != NULL) {
> > -        pci_create_simple(bus, -1, "xen-platform");
> > +        pci_create_simple(bus, PCI_DEVFN(3, 0), "xen-platform");
> >      }
> >  }
> >  #endif
> > 
> > 
> > The same thing could be done by libxl, by providing specific command
> > line options to qemu. (I think that could even be done via a different
> > config file for the guest.)
> 
> This patch doesn't seem to work for me.  It seems like the device model
> process is exiting immediately, but I haven't been able to find any
> information as to what is going wrong.  I tested with Xen 4.6.6 and the
> QEMU packaged with that release.  Should I try it on a different version
> of Xen and QEMU?

What this patch does is asking QEMU to insert the PCI card
"xen-platform" into the 3rd PCI slot. My guess is that failed because
there is already a PCI device there.

You could check qemu's logs, it's in
/var/log/xen/qemu-dm-${guest_name}.log


Let's try something else, instead of patching QEMU, we can patch libxl,
that might work better. Can you try this patch? (I've only test
compiled.) I've write the patch for Xen 4.6, since that the version you
are using.


From: Anthony PERARD <anthony.perard@xxxxxxxxxx>
Subject: [PATCH] libxl_dm: Explicitly put xen-platform device on PCI slot 3

In order to do that, we don't use xenfv machine anymore and explicity
add the platform device on the command line.

Signed-off-by: Anthony PERARD <anthony.perard@xxxxxxxxxx>
---
 tools/libxl/libxl_dm.c | 11 ++++++-----
 1 file changed, 6 insertions(+), 5 deletions(-)

diff --git a/tools/libxl/libxl_dm.c b/tools/libxl/libxl_dm.c
index 0db5f13553..59c0102a3e 100644
--- a/tools/libxl/libxl_dm.c
+++ b/tools/libxl/libxl_dm.c
@@ -899,6 +899,11 @@ static int libxl__build_device_model_args_new(libxl__gc 
*gc,
             }
         }
 
+        if (libxl_defbool_val(b_info->u.hvm.xen_platform_pci)) {
+            flexarray_vappend(dm_args, "-device",
+                              "xen-platform,addr=3", NULL);
+        }
+
         if (libxl_defbool_val(b_info->u.hvm.nographic) && (!sdl && !vnc)) {
             flexarray_append(dm_args, "-nographic");
         }
@@ -1075,14 +1080,10 @@ static int libxl__build_device_model_args_new(libxl__gc 
*gc,
             flexarray_append(dm_args, b_info->extra_pv[i]);
         break;
     case LIBXL_DOMAIN_TYPE_HVM:
-        if (!libxl_defbool_val(b_info->u.hvm.xen_platform_pci)) {
             /* Switching here to the machine "pc" which does not add
              * the xen-platform device instead of the default "xenfv" machine.
              */
-            machinearg = libxl__sprintf(gc, "pc,accel=xen");
-        } else {
-            machinearg = libxl__sprintf(gc, "xenfv");
-        }
+        machinearg = libxl__sprintf(gc, "pc,accel=xen");
         if (b_info->u.hvm.mmio_hole_memkb) {
             uint64_t max_ram_below_4g = (1ULL << 32) -
                 (b_info->u.hvm.mmio_hole_memkb << 10);

-- 
Anthony PERARD

_______________________________________________
Xen-devel mailing list
Xen-devel@xxxxxxxxxxxxxxxxxxxx
https://lists.xenproject.org/mailman/listinfo/xen-devel

 


Rackspace