[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] Re: [Xen-devel] [PATCH v2 07/11] IOMMU/MMU: propagate IOMMU Device-TLB flush error up to iommu_iotlb_flush{, _all} (top level ones).
>>> On 27.04.16 at 08:21, <quan.xu@xxxxxxxxx> wrote:
> On April 26, 2016 8:49 PM, Jan Beulich <JBeulich@xxxxxxxx> wrote:
>> Hmm, the "positive" here has nothing to do with the "positive" in patch 1.
>> Please just have a look at xenmem_add_to_physmap() as a whole.
>>
>
> Thanks for reminding me. The 'positive' is ' rc = start + done'..
>
> Think twice, I found I need two other new return values for this function
> (correct me if I am wrong!).
> If the first iommu_iotlb_flush() is failed, I shouldn't accumulate the
> return value of
> the second iommu_iotlb_flush() -- but instead properly accumulate the return
> value.
I think just one will do.
> The following is my modification:
>
> --- a/xen/common/memory.c
> +++ b/xen/common/memory.c
> @@ -640,6 +640,10 @@ static int xenmem_add_to_physmap(struct domain *d,
> unsigned int done = 0;
> long rc = 0;
>
> +#ifdef CONFIG_HAS_PASSTHROUGH
> + int ret, rv;
> +#endif
This should go into the scope below, allowing to avoid the extra
#ifdef.
> @@ -678,8 +682,15 @@ static int xenmem_add_to_physmap(struct domain *d,
> if ( need_iommu(d) )
> {
> this_cpu(iommu_dont_flush_iotlb) = 0;
> - iommu_iotlb_flush(d, xatp->idx - done, done);
> - iommu_iotlb_flush(d, xatp->gpfn - done, done);
> + ret = iommu_iotlb_flush(d, xatp->idx - done, done);
> +
> + if ( rc >= 0 && ret < 0 )
Why "ret < 0" instead of just "ret"?
> + rc = ret;
> +
> + rv = iommu_iotlb_flush(d, xatp->gpfn - done, done);
> +
> + if ( rc >=0 && ret == 0 && rv < 0 )
> + rc = rv;
I don't see the middle part being needed here, eliminating the
need for "rv".
Jan
_______________________________________________
Xen-devel mailing list
Xen-devel@xxxxxxxxxxxxx
http://lists.xen.org/xen-devel
|
![]() |
Lists.xenproject.org is hosted with RackSpace, monitoring our |