On Mon, Mar 23, 2015 at 9:00 PM, Julien Grall <julien.grall@xxxxxxxxxx> wrote:
> On 23/03/15 15:18, Vijay Kilari wrote:
>>> The ITS still have to manage in someway the device. There is lots of
>>> information that doesn't need to be created at every mapd (such as the
>>> number of MSI).
>>
>> First assumption is VITS driver owns converting Virtual ITS commands
>>  to Physical ITS commands. So based on this
>>
>> - arch_domain contains list of all the devices attached for the domain.
>> -  On MAPD command, device is created, physical LPI's and virtual LPIs
>> are allocated
>>    and added to domains list and further all other ITS commands except
>> MAPC, INVALL and SYNC
>>    depend on device information to convert virtual ITS commands to
>> physical ITS commands.
>
> I didn't understand what you said.

I mean, all the virtual ITS commands has to be converted to
physical ITS commands. The (most)information required to do this conversion
is based on device_id for most of the commands (except MAPC, SYNC & INVALL)
So vITS driver contains device management.
However, all the devices managed using linked list attached to a domain.

Few API's are added in physical ITS driver to query
Physical Collection ID (pCID) to Virtual Collection ID (vCID) and
Virtual Target address(vTA)
 to Physical Target Address(pTA) because pCID & pTA info is available
in physical ITS driver.

Refer to : 4.9.22 Command Mapping for a Guest with a GICv3 ITS
of PRD03-GENC-010745 20.0

Overall the functionality was split as follows;

- Physical ITS driver manages Physical LPI allocation, Sending
Physical commands,
  Physical Collection ID & Target addresses
- Virtual ITS driver manages Virtual LPI allocation, Device creation
for respective domain,
  Conversion of virtual ITS commands to Physical ITS commands, Virtual
Collection ID's
  Virtual Target address, GITS register emulation, LPI
pending/Property table emulation.

It would be better if you go through the patch set and comment under
relevant code
and we can discuss.

>
>>>
>>> Handling device management in ITS would help to check the validity of
>>> the access. Which you are currently ignoring...
>>>
>>>>>
>>>>> How do you check if the domain can use the device?
>>>>> Currently, you allow any domain to use any device. That would bring a big
>>>>> mess with guest using passthrough.
>>>>
>>>> ITS driver does not know which PCI device is assigned for which domain.
>>>
>>> Wrong, Xen knows which device is assigned to which domain so ITS does.
>>>
>>>> I think it should be done by above layers along with pci drivers in Xen.
>>>> vITS assume that the domain that sends MAPD command owns the device
>>>
>>> The vITS emulates hardware for a specific domain. A malicious guest
>>> could send request to a not own device.
>>
>> OK.   On MAPD command when ITS device is created, I can introduce pci helper
>> function to know if particular device is assigned to domain or not.
>>
>>>
>>> You have to think about security in the vITS otherwise we will end up
>>> with many XSA in this code...
>>>
>>
>>  For every virtual ITS command parameters are validated
>> before issuing physical command, except check on device id which I will
>> take care in next version
>
> The check on device id is not the only check missing... You also have to
> validate ID, Size... with the number of bits supported by the ITS.
>