[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [Xen-devel] Unable to switch input to xen from serial console



On Wed, 2008-07-02 at 17:42 +0100, Tim Deegan wrote:
> Oh!  I wonder why it's showing up as ttyS1.  Yes, changing the Xen
> command line to have "console=com2,vga com2=115200,8n1" should work
> then.  
yes it worked..and its breaking into hypervisor kdb as well now.
 thanks a lot Tim & keir