[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[Xen-devel] Re: [PATCH] PV Passthrough PCI Device Hotplug Support (Tools Part)



Yosuke,

Thanks for you work.
I have tested your patch works on HVM VT-d side.

One suggestion is error handling for user input. e.g. following input error 
should be caught by xm:

[root@vt-gang32 ~]# xm pci-attach EdwinHVMDomainVtd2 0:2.0.0    (should be 
0:2:0.0)

Error: pci: failed to locate device and parse it's resources - [Errno 2] No 
such 
file or directory: '/sys/bus/pci/devices/0000:00:02.0/driver'
Usage: xm pci-attach <Domain> <domain:bus:slot.func> [virtual slot]



On Mon, Mar 10, 2008 at 10:19:10AM +0900, Yosuke Iwamatsu wrote:
> Hi,
> 
> This is the updated patch of PV PCI passthrough hotplug (tools portion).
> 
> Changes to xm command:
> - Let 'xm pci-attach' command use <domain:bus:slot.func> expression
>   rather than use separated arguments like <domain> <bus> <slot> <func>.
>   This is the same expression of the domain configuration file and I
>   believe it is more user-friendly.
> - Let 'xm pci-detach' command use the same <domain:bus:slot.func>
>   expression. Formerly, <virtual slot> was used as the key to indicate
>   which device we were detaching. But for the current implementation of
>   PV PCI hotplug, virtual slots don't have much meaning. I think using
>   the same physical device name in both attachment and detachment is
>   appropriate here.
> 
> Changes to xend:
> - Both attach and detach commands are received by device_configure()
>   and handled by pci_device_configure().
> - HVM specific processings are done in hvm_pci_create_device() and
>   hvm_destroyPCIDevice().
> 
> The major problem I encoutered during this work is that, I don't have
> a vt-d enabled machine and could not confirm that HVM PCI hotplug would
> still work after modifications :-(
> Then I hacked libxc a little to pretend as if there existed a vt-d
> hardware, and could see HVM PCI attach/detach working correctly.
> So now I'm pretty sure that we can do both PV and HVM hotplugs with
> this patch, but I would appreciate it if someone could test this on
> a real vt-d machine.
> 
> Regards,
> -------------------
> Yosuke Iwamatsu
>         NEC Corporation
> 



-- 
best rgds,
edwin

_______________________________________________
Xen-devel mailing list
Xen-devel@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-devel


 