[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [XENBUS PATCH v3 5/5] Check for active installation before autoreboot
If the _MSIExecute mutex is set, an MSI installation is under way.
We don't want to autoreboot in these situations either.
Signed-off-by: Tu Dinh <ngoc-tu.dinh@xxxxxxxxxx>
Reviewed-by: Paul Durrant <paul@xxxxxxx>
---
src/monitor/monitor.c | 17 +++++++++++++++++
1 file changed, 17 insertions(+)
diff --git a/src/monitor/monitor.c b/src/monitor/monitor.c
index 8a56c11..dd5fc13 100644
--- a/src/monitor/monitor.c
+++ b/src/monitor/monitor.c
@@ -686,6 +686,7 @@ TryAutoReboot(
{
PMONITOR_CONTEXT Context = &MonitorContext;
HRESULT Result;
+ HANDLE MsiMutex;
DWORD Type;
DWORD AutoReboot;
DWORD RebootCount;
@@ -711,6 +712,22 @@ TryAutoReboot(
if (Context->Response == IDNO)
goto done;
+ // Check if there's an installation under way.
+ MsiMutex = OpenMutex(SYNCHRONIZE,
+ FALSE,
+ TEXT("Global\\_MSIExecute"));
+ if (MsiMutex != NULL) {
+ Error = WaitForSingleObject(MsiMutex, 0);
+ if (Error == WAIT_OBJECT_0 || Error == WAIT_ABANDONED)
+ ReleaseMutex(MsiMutex);
+
+ CloseHandle(MsiMutex);
+
+ if (Error == WAIT_TIMEOUT)
+ // The only case where an installation is definitely running.
+ goto done;
+ }
+
Status = CallNtPowerInformation(SystemExecutionState,
NULL,
0,
--
2.49.0.windows.1
Ngoc Tu Dinh | Vates XCP-ng Developer
XCP-ng & Xen Orchestra - Vates solutions
web: https://vates.tech
|
![]() |
Lists.xenproject.org is hosted with RackSpace, monitoring our |