xen-users
Re: [Xen-users] Graceful Shutdown For Windows Domain?
Windows should be fine with ACPI signals assuming it has sufficient drivers to
detect this functionality 'from the BIOS'.
Can't comment on the GPLPV drivers but I'd imagine if they include a shut down
service this would be how it's being accomplished.
Check out this:
http://msdn.microsoft.com/en-us/library/aa939200(v=winembedded.5).aspx
Seems to make out that the power button is controlled via ACPI. Therefore if
you have booted your VM with "acpi = 0" in domU cfg then it's highly unlikely
you will be able to trigger a graceful shut down.
Iain Kay
On 19 May 2011, at 18:28, Steven Timm wrote:
>
> Is windows sensitive to the ACPI signals? that is what Xen uses
> to talk to Linux VM's if I understand it correctly.
>
> Steve Timm
>
> On Thu, 19 May 2011, John Backes wrote:
>
>> Hi,
>>
>> I was wondering if there is anyway to gracefully shutdown a Windows domain?
>> The xm shutdown command essentially "cuts power off" to the machine.
>>
>> Thanks.
>>
>> _______________________________________________
>> Xen-users mailing list
>> Xen-users@xxxxxxxxxxxxxxxxxxx
>> http://lists.xensource.com/xen-users
>>
>
> --
> ------------------------------------------------------------------
> Steven C. Timm, Ph.D (630) 840-8525
> timm@xxxxxxxx http://home.fnal.gov/~timm/
> Fermilab Computing Division, Scientific Computing Facilities,
> Grid Facilities Department, FermiGrid Services Group, Group Leader.
> Lead of FermiCloud project.
>
> _______________________________________________
> Xen-users mailing list
> Xen-users@xxxxxxxxxxxxxxxxxxx
> http://lists.xensource.com/xen-users
_______________________________________________
Xen-users mailing list
Xen-users@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-users
|
|
|
|
|