xen-changelog
[Xen-changelog] [xen-unstable] blkif interface: Add BLKIF_OP_FLUSH_DISKC
# HG changeset patch
# User Keir Fraser <keir.fraser@xxxxxxxxxx>
# Date 1196765428 0
# Node ID ebfb3b26010da86328d3844fe37fe20e9170d6ba
# Parent b1da8762f85312656b19a905903ddf06fe0bacf2
blkif interface: Add BLKIF_OP_FLUSH_DISKCACHE.
This disk operation, implemented on Solaris only so far, asks a
backend to flush the disk caches of the underlying storage if
possible, and is contigent upon the 'feature-flush-cache' xenstore
flag (although currently Solaris will always attempt to flush
anyway).
Signed-off-by: John Levon <john.levon@xxxxxxx>
---
xen/include/public/io/blkif.h | 15 ++++++++++++++-
1 files changed, 14 insertions(+), 1 deletion(-)
diff -r b1da8762f853 -r ebfb3b26010d xen/include/public/io/blkif.h
--- a/xen/include/public/io/blkif.h Tue Dec 04 10:48:28 2007 +0000
+++ b/xen/include/public/io/blkif.h Tue Dec 04 10:50:28 2007 +0000
@@ -54,7 +54,7 @@
#define BLKIF_OP_WRITE 1
/*
* Recognised only if "feature-barrier" is present in backend xenbus info.
- * The "feature_barrier" node contains a boolean indicating whether barrier
+ * The "feature-barrier" node contains a boolean indicating whether barrier
* requests are likely to succeed or fail. Either way, a barrier request
* may fail at any time with BLKIF_RSP_EOPNOTSUPP if it is unsupported by
* the underlying block-device hardware. The boolean simply indicates whether
@@ -63,6 +63,19 @@
* create the "feature-barrier" node!
*/
#define BLKIF_OP_WRITE_BARRIER 2
+/*
+ * Recognised if "feature-flush-cache" is present in backend xenbus
+ * info. A flush will ask the underlying storage hardware to flush its
+ * non-volatile caches as appropriate. The "feature-flush-cache" node
+ * contains a boolean indicating whether flush requests are likely to
+ * succeed or fail. Either way, a flush request may fail at any time
+ * with BLKIF_RSP_EOPNOTSUPP if it is unsupported by the underlying
+ * block-device hardware. The boolean simply indicates whether or not it
+ * is worthwhile for the frontend to attempt flushes. If a backend does
+ * not recognise BLKIF_OP_WRITE_FLUSH_CACHE, it should *not* create the
+ * "feature-flush-cache" node!
+ */
+#define BLKIF_OP_FLUSH_DISKCACHE 3
/*
* Maximum scatter/gather segments per request.
_______________________________________________
Xen-changelog mailing list
Xen-changelog@xxxxxxxxxxxxxxxxxxx
http://lists.xensource.com/xen-changelog
|
<Prev in Thread] |
Current Thread |
[Next in Thread> |
- [Xen-changelog] [xen-unstable] blkif interface: Add BLKIF_OP_FLUSH_DISKCACHE.,