Re: [Xen-ia64-devel] DomVTi with PV-on-HVM drivers causes the hypervisor

To: KUWAMURA Shin'ya <kuwa@xxxxxxxxxxxxxx>
Subject: Re: [Xen-ia64-devel] DomVTi with PV-on-HVM drivers causes the hypervisor panic
From: Isaku Yamahata <yamahata@xxxxxxxxxxxxx>
Date: Mon, 28 Jul 2008 16:41:38 +0900
Cc: xen-ia64-devel@xxxxxxxxxxxxxxxxxxx
Delivery-date: Mon, 28 Jul 2008 00:41:42 -0700
Envelope-to: www-data@xxxxxxxxxxxxxxxxxxx
In-reply-to: <20080725.192042.10306892.kuwa@xxxxxxxxxxxxxx>
List-help: <mailto:xen-ia64-devel-request@lists.xensource.com?subject=help>
List-id: Discussion of the ia64 port of Xen <xen-ia64-devel.lists.xensource.com>
List-post: <mailto:xen-ia64-devel@lists.xensource.com>
List-subscribe: <http://lists.xensource.com/mailman/listinfo/xen-ia64-devel>, <mailto:xen-ia64-devel-request@lists.xensource.com?subject=subscribe>
List-unsubscribe: <http://lists.xensource.com/mailman/listinfo/xen-ia64-devel>, <mailto:xen-ia64-devel-request@lists.xensource.com?subject=unsubscribe>
References: <20080725.163725.139539114.kuwa@xxxxxxxxxxxxxx> <20080725091639.GM2117%yamahata@xxxxxxxxxxxxx> <20080725.192042.10306892.kuwa@xxxxxxxxxxxxxx>
Sender: xen-ia64-devel-bounces@xxxxxxxxxxxxxxxxxxx
User-agent: Mutt/1.5.6i
On Fri, Jul 25, 2008 at 07:20:42PM +0900, KUWAMURA Shin'ya wrote:
> Hi,
> 
> From: Isaku Yamahata <yamahata@xxxxxxxxxxxxx>
> Subject: Re: [Xen-ia64-devel] DomVTi with PV-on-HVM drivers causes the 
> hypervisor panic
> Date: Fri, 25 Jul 2008 18:16:39 +0900
> 
> > Is domid 6 HVM domain which is to create here?
> 
> Yes. The same HVM domain was created six times.
> Domid 1-5 was created without PV-on-HVM drivers,
>  and domid 6 was created with PV-on-HVM drivers.
> 
> Thus, this issue was caused by PV-on-HVM drivers.

I see.
Hmm, I'm afraind that c/s 18090:1e5d42cf61ec may cause the issue.
Could you please test again without c/s 18090:1e5d42cf61ec.

-- 
yamahata