Patch sends a UNIT_ATTENTION(6), MEDIUM_MAY_HAVE_CHANGED(0x28) sense
when cdrom transitions from not ready to ready.
ATA Packet interface for CD-ROMS, SFF8020i.pdf. See state diagram Figure
12, page 82 and Table 44 -recommended Sense Key, ASC
With patch in place HVM win2008 server guest sees the CD/DVD contents
have changed when the media is switched.
Please apply to xen-unstable tip.
Signed-off-by: Pat Campbell <plc@xxxxxxxxxx>
diff -r af8da3f10449 tools/ioemu/hw/ide.c
--- a/tools/ioemu/hw/ide.c Tue May 13 11:46:39 2008 -0600
+++ b/tools/ioemu/hw/ide.c Tue May 13 06:42:09 2008 -0600
@@ -289,6 +289,7 @@
#define ASC_ILLEGAL_OPCODE 0x20
#define ASC_LOGICAL_BLOCK_OOR 0x21
#define ASC_INV_FIELD_IN_CMD_PACKET 0x24
+#define ASC_MEDIUM_MAY_HAVE_CHANGED 0x28
#define ASC_MEDIUM_NOT_PRESENT 0x3a
#define ASC_SAVING_PARAMETERS_NOT_SUPPORTED 0x39
@@ -1456,6 +1457,11 @@ static void ide_atapi_cmd(IDEState *s)
switch(s->io_buffer[0]) {
case GPCMD_TEST_UNIT_READY:
if (bdrv_is_inserted(s->bs)) {
+ if (s->is_cdrom && s->sense_key == SENSE_NOT_READY) {
+ ide_atapi_cmd_error(s, SENSE_UNIT_ATTENTION,
+ ASC_MEDIUM_MAY_HAVE_CHANGED);
+ break;
+ }
ide_atapi_cmd_ok(s);
} else {
ide_atapi_cmd_error(s, SENSE_NOT_READY,
_______________________________________________